Skip to content

Local water dashboard

Official source aggregation

Water quality in Eloy, AZ 85131

A source-transparent look at local hardness, associated public water systems, EPA compliance history, and the measurements that are—and are not—available for Pinal County.

1 reported benchmark flag
Primary matched system
Cca - Eloy Complex
Source water
Groundwater
County
Pinal County
Profile updated

At a glance

What the current records say

Hardness

Very Hard

306.5 PPM · 17.9 GPG

Compliance screen

No active flag

0 active health-based records

Lead 90th percentile

0 mg/L

0% of action level

Utility match

4 systems

Serves 8,852 people system-wide

Hardness meter

How hard is the water?

Very Hard

Estimated local hardness

USGS hardness classification scale

306.5 PPM

Soft
0–59
Moderate
60–120
Hard
121–180
Very hard
181+

Parts per million

306.5

mg/L as CaCO₃ equivalent

Grains per gallon

17.9

1 GPG ≈ 17.1 PPM

What this means at home

At 306.5 PPM, mineral scale can build up on fixtures and heating elements, reduce soap lather, and leave visible spotting. Hardness is primarily an aesthetic and appliance concern—not itself a tap-water safety rating.

USGS sites used

24

Nearest site

35.1 mi

Observation range

Jan 11, 2016–Dec 17, 2024

Estimate confidence

Low

Median of the latest qualifying hardness observation at each nearby monitoring site. Nearest monitoring location: D-13-12 03BCC1 (Well).USGS source documentation ↗

Regional context

Is 85131 typical?

These comparisons use other indexed ZIP estimates, not utility tap samples. They help show local context without replacing a household test.

Eloy median

297 PPM

10 PPM higher

2 indexed ZIP readings · Range 288–306.5 PPM

Arizona median

241 PPM

66 PPM higher

285 indexed ZIP readings · Range 66.4–1250 PPM

EPA benchmark screen

Contaminant snapshot

Available numerical results from associated SDWIS community water systems, compared with the applicable action level or federal MCL. Federal measured-value coverage is incomplete.

1 pass1 fail

Lead (PB90)

0 mg/L

Reported Dec 31, 2027

Copper (CU90)

Not available

No numerical 90th-percentile result

Numerical coverage

2 comparable results

Missing values remain blank; absence is not treated as a pass.

Lead (90th percentile)

Measured in mg/L

Pass

Local 0

EPA limit 0.015

Local level is 0% of the listed EPA limit.

Nitrate

Measured in MG/L

Fail

Local 11

EPA limit 10

Local level is 110% of the listed EPA limit.

Share of EPA benchmark

100% line = listed limit

EPA SDWIS compliance

Reported violation history

Open EPA source documentation ↗
2026Q2
All records
84
Health-based
19
Active health-based
0
Contaminant or ruleSystemStatusPeriod
NitrateHealth-basedReported 11 MG/L · MCL 10AZ0411030ArchivedJan 1, 2026through Mar 31, 2026
NitrateHealth-basedReported 11 MG/L · MCL 10AZ0411030ArchivedJan 1, 2026through Mar 31, 2026
Lead and Copper RuleAZ0411005ResolvedJan 1, 2026through Mar 26, 2026
Revised Total Coliform RuleAZ0411030ResolvedDec 1, 2025through Dec 31, 2025
Consumer Confidence RuleAZ0411005ResolvedOct 2, 2025through Oct 14, 2025
Consumer Confidence RuleAZ0411321ResolvedOct 2, 2025through Oct 14, 2025
ArsenicAZ0411115ResolvedOct 1, 2025through Dec 31, 2025
Lead and Copper RuleAZ0411030ResolvedOct 1, 2025through Nov 14, 2025
ChlorineAZ0411005ResolvedMay 1, 2025through May 31, 2025
ChlorineAZ0411321ResolvedMay 1, 2025through May 31, 2025
NitrateHealth-basedReported 33 MG/L · MCL 10AZ0411005ResolvedJan 1, 2025through Dec 31, 2025
Lead and Copper RuleAZ0411005ResolvedJan 1, 2025through Nov 1, 2024
Lead and Copper RuleAZ0411321ResolvedJan 1, 2025through Oct 4, 2024
NitrateHealth-basedReported 19 MG/L · MCL 10AZ0411321ResolvedOct 1, 2024through Dec 31, 2024
TTHMAZ0411030ResolvedJul 1, 2024through Sep 30, 2024
Total Haloacetic Acids (HAA5)AZ0411030ResolvedJul 1, 2024through Sep 30, 2024
Total Haloacetic Acids (HAA5)AZ0411321ResolvedJul 1, 2024through Sep 30, 2024
TTHMAZ0411321ResolvedJul 1, 2024through Sep 30, 2024
NitrateHealth-basedReported 17 MG/L · MCL 10AZ0411321ResolvedJul 1, 2024through Sep 30, 2024
Revised Total Coliform RuleAZ0411115ResolvedJun 1, 2024through Aug 13, 2024

No reported violation does not prove that every contaminant was tested or absent; SDWIS measured values are incomplete and lag state records.

Solutions matcher

Your personalized water action plan

Matched to Eloy ZIP 85131 using 306.5 PPM nearby hardness and 2 reported measurement benchmarks.

2 matches

Scale protection

High-Capacity Whole House Water Softener

306.5 PPM is 3× the high-hardness trigger used by this matcher.

Designed to reduce scale on fixtures, water heaters, glassware, and plumbing throughout the home.

Compare whole-house systems

Drinking water protection

Under-Sink Reverse Osmosis System

Nitrate has a measured benchmark flag or active health-based SDWIS record in this profile.

A certified multi-stage RO system targets a broader range of dissolved contaminants at the kitchen tap.

Explore under-sink filtration

Affiliate disclosure: we may earn a commission from qualifying purchases, at no added cost to you. Product matching is educational and does not replace certified water testing.

Nearby indexed reports

Compare ZIPs in Eloy

Estimates can differ across a city because monitoring locations and associated systems differ.

View all Eloy reports →

Frequently asked

Water questions for Eloy

Is tap water safe in Eloy?+

EPA ECHO shows no active health-based violation for the associated systems in this reporting snapshot. This does not prove every contaminant is absent; federal records can lag and household plumbing can change tap conditions.

How hard is the water?+

Nearby USGS observations produce an estimate of 306.5 PPM, or 17.9 grains per gallon, classified as very hard. This is not a household tap measurement.

Do I need a water softener?+

At 306.5 PPM, a correctly sized whole-house softener can reduce scale and hard-water spotting. It does not replace contaminant filtration.