Skip to content

Local water dashboard

Official source aggregation

Water quality in East Palatka, FL 32131

A source-transparent look at local hardness, associated public water systems, EPA compliance history, and the measurements that are—and are not—available for Putnam County.

1 reported benchmark flag
Primary matched system
East Putnam Regional
Source water
Groundwater
County
Putnam County
Profile updated

At a glance

What the current records say

Hardness

Very Hard

280 PPM · 16.4 GPG

Compliance screen

No active flag

0 active health-based records

Lead 90th percentile

3.0e-4 mg/L

2% of action level

Utility match

3 systems

Serves 1,500 people system-wide

Hardness meter

How hard is the water?

Very Hard

Estimated local hardness

USGS hardness classification scale

280 PPM

Soft
0–59
Moderate
60–120
Hard
121–180
Very hard
181+

Parts per million

280

mg/L as CaCO₃ equivalent

Grains per gallon

16.4

1 GPG ≈ 17.1 PPM

What this means at home

At 280 PPM, mineral scale can build up on fixtures and heating elements, reduce soap lather, and leave visible spotting. Hardness is primarily an aesthetic and appliance concern—not itself a tap-water safety rating.

USGS sites used

12

Nearest site

16.6 mi

Observation range

Nov 20, 2019–Jan 21, 2026

Estimate confidence

Moderate

Median of the latest qualifying hardness observation at each nearby monitoring site. Nearest monitoring location: Palm Coast SA Well SW-126 AAL2093 (Well).USGS source documentation ↗

Regional context

Is 32131 typical?

These comparisons use other indexed ZIP estimates, not utility tap samples. They help show local context without replacing a household test.

East Palatka median

280 PPM

About the same

1 indexed ZIP readings · Range 280–280 PPM

Florida median

280 PPM

About the same

602 indexed ZIP readings · Range 20–374.5 PPM

EPA benchmark screen

Contaminant snapshot

Available numerical results from associated SDWIS community water systems, compared with the applicable action level or federal MCL. Federal measured-value coverage is incomplete.

1 pass1 fail

Lead (PB90)

3.0e-4 mg/L

Reported Dec 1, 2025

Copper (CU90)

Not available

No numerical 90th-percentile result

Numerical coverage

2 comparable results

Missing values remain blank; absence is not treated as a pass.

Lead (90th percentile)

Measured in mg/L

Pass

Local 3.0e-4

EPA limit 0.015

Local level is 2% of the listed EPA limit.

TTHM

Measured in UG/L

Fail

Local 81.35

EPA limit 0.08

Local level is 101687% of the listed EPA limit.

Share of EPA benchmark

100% line = listed limit

EPA SDWIS compliance

Reported violation history

Open EPA source documentation ↗
2026Q2
All records
45
Health-based
2
Active health-based
0
Contaminant or ruleSystemStatusPeriod
Revised Total Coliform RuleFL2544444ResolvedFeb 1, 2026through Feb 28, 2026
E. COLIFL2544444ResolvedFeb 1, 2026through Feb 28, 2026
Revised Total Coliform RuleFL2544444ResolvedJan 1, 2026through Jan 31, 2026
E. COLIFL2544444ResolvedJan 1, 2026through Jan 31, 2026
E. COLIFL2544444ResolvedJul 1, 2025through Jul 31, 2025
Revised Total Coliform RuleFL2544444ResolvedJul 1, 2025through Jul 31, 2025
Revised Total Coliform RuleFL2544444ResolvedJun 1, 2025through Jun 30, 2025
E. COLIFL2544444ResolvedJun 1, 2025through Jun 30, 2025
E. COLIFL2544444ResolvedMay 1, 2025through May 31, 2025
Revised Total Coliform RuleFL2544444ResolvedMay 1, 2025through May 31, 2025
Revised Total Coliform RuleFL2544444ResolvedMar 1, 2025through Mar 31, 2025
E. COLIFL2544444ResolvedMar 1, 2025through Mar 31, 2025
E. COLIFL2540865ResolvedMar 1, 2025through Mar 31, 2025
Revised Total Coliform RuleFL2540865ResolvedMar 1, 2025through Mar 31, 2025
E. COLIFL2544444ResolvedFeb 1, 2025through Feb 12, 2025
Revised Total Coliform RuleFL2544444ResolvedFeb 1, 2025through Feb 12, 2025
Revised Total Coliform RuleFL2544444ResolvedJan 1, 2025through Jan 31, 2025
TTHMFL2544444ArchivedJan 1, 2025through Dec 31, 2025
Total Haloacetic Acids (HAA5)FL2544444ArchivedJan 1, 2025through Dec 31, 2025
E. COLIFL2544444ResolvedJan 1, 2025through Jan 31, 2025

No reported violation does not prove that every contaminant was tested or absent; SDWIS measured values are incomplete and lag state records.

Solutions matcher

Your personalized water action plan

Matched to East Palatka ZIP 32131 using 280 PPM nearby hardness and 2 reported measurement benchmarks.

2 matches

Scale protection

High-Capacity Whole House Water Softener

280 PPM is 2× the high-hardness trigger used by this matcher.

Designed to reduce scale on fixtures, water heaters, glassware, and plumbing throughout the home.

Compare whole-house systems

Drinking water protection

Under-Sink Reverse Osmosis System

TTHM has a measured benchmark flag or active health-based SDWIS record in this profile.

A certified multi-stage RO system targets a broader range of dissolved contaminants at the kitchen tap.

Explore under-sink filtration

Affiliate disclosure: we may earn a commission from qualifying purchases, at no added cost to you. Product matching is educational and does not replace certified water testing.

Frequently asked

Water questions for East Palatka

Is tap water safe in East Palatka?+

EPA ECHO shows no active health-based violation for the associated systems in this reporting snapshot. This does not prove every contaminant is absent; federal records can lag and household plumbing can change tap conditions.

How hard is the water?+

Nearby USGS observations produce an estimate of 280 PPM, or 16.4 grains per gallon, classified as very hard. This is not a household tap measurement.

Do I need a water softener?+

At 280 PPM, a correctly sized whole-house softener can reduce scale and hard-water spotting. It does not replace contaminant filtration.