Skip to content

Local water dashboard

Official source aggregation

Water quality in Maysville, GA 30558

A source-transparent look at local hardness, associated public water systems, EPA compliance history, and the measurements that are—and are not—available for Jackson County.

2 reported benchmark flags
Primary matched system
Maysville Water System
Source water
Surface water
County
Jackson County
Profile updated

At a glance

What the current records say

Hardness

Soft

23.5 PPM · 1.4 GPG

Compliance screen

No active flag

0 active health-based records

Lead 90th percentile

0.0023 mg/L

15% of action level

Utility match

1 system

Serves 2,838 people system-wide

Hardness meter

How hard is the water?

Soft

Estimated local hardness

USGS hardness classification scale

23.5 PPM

Soft
0–59
Moderate
60–120
Hard
121–180
Very hard
181+

Parts per million

23.5

mg/L as CaCO₃ equivalent

Grains per gallon

1.4

1 GPG ≈ 17.1 PPM

What this means at home

At 23.5 PPM, mineral scale can build up on fixtures and heating elements, reduce soap lather, and leave visible spotting. Hardness is primarily an aesthetic and appliance concern—not itself a tap-water safety rating.

USGS sites used

20

Nearest site

14.2 mi

Observation range

Jan 5, 2016–Jun 3, 2026

Estimate confidence

Moderate

Median of the latest qualifying hardness observation at each nearby monitoring site. Nearest monitoring location: CHATTAHOOCHEE RIVER BELTON BRIDGE ROAD NR LULA, GA (Stream).USGS source documentation ↗

Regional context

Is 30558 typical?

These comparisons use other indexed ZIP estimates, not utility tap samples. They help show local context without replacing a household test.

Maysville median

24 PPM

About the same

1 indexed ZIP readings · Range 23.5–23.5 PPM

Georgia median

40 PPM

16 PPM lower

469 indexed ZIP readings · Range 3–207 PPM

EPA benchmark screen

Contaminant snapshot

Available numerical results from associated SDWIS community water systems, compared with the applicable action level or federal MCL. Federal measured-value coverage is incomplete.

1 pass2 fail

Lead (PB90)

0.0023 mg/L

Reported Dec 31, 2023

Copper (CU90)

Not available

No numerical 90th-percentile result

Numerical coverage

3 comparable results

Missing values remain blank; absence is not treated as a pass.

Lead (90th percentile)

Measured in mg/L

Pass

Local 0.0023

EPA limit 0.015

Local level is 15% of the listed EPA limit.

Total Haloacetic Acids (HAA5)

Measured in MG/L

Fail

Local 0.063

EPA limit 0.06

Local level is 105% of the listed EPA limit.

TTHM

Measured in MG/L

Fail

Local 0.083

EPA limit 0.08

Local level is 104% of the listed EPA limit.

Share of EPA benchmark

100% line = listed limit

EPA SDWIS compliance

Reported violation history

Open EPA source documentation ↗
2026Q2
All records
24
Health-based
10
Active health-based
0
Contaminant or ruleSystemStatusPeriod
Total Haloacetic Acids (HAA5)Health-basedReported 0.063 MG/L · MCL 0.06GA0110001ResolvedApr 1, 2024through Jun 30, 2024
Total Haloacetic Acids (HAA5)Health-basedReported 0.063 MG/L · MCL 0.06GA0110001ResolvedJan 1, 2024through Mar 31, 2024
Total Haloacetic Acids (HAA5)Health-basedReported 0.062 MG/L · MCL 0.06GA0110001ResolvedOct 1, 2023through Dec 31, 2023
Total Haloacetic Acids (HAA5)Health-basedReported 0.063 MG/L · MCL 0.06GA0110001ResolvedJul 1, 2023through Sep 30, 2023
CadmiumGA0110001ArchivedJan 1, 2023through Dec 31, 2025
NickelGA0110001ArchivedJan 1, 2023through Dec 31, 2025
Beryllium, TotalGA0110001ArchivedJan 1, 2023through Dec 31, 2025
SeleniumGA0110001ArchivedJan 1, 2023through Dec 31, 2025
CYANIDEGA0110001ArchivedJan 1, 2023through Dec 31, 2025
BariumGA0110001ArchivedJan 1, 2023through Dec 31, 2025
FluorideGA0110001ArchivedJan 1, 2023through Dec 31, 2025
Thallium, TotalGA0110001ArchivedJan 1, 2023through Dec 31, 2025
ArsenicGA0110001ArchivedJan 1, 2023through Dec 31, 2025
MercuryGA0110001ArchivedJan 1, 2023through Dec 31, 2025
ChromiumGA0110001ArchivedJan 1, 2023through Dec 31, 2025
Antimony, TotalGA0110001ArchivedJan 1, 2023through Dec 31, 2025
TTHMHealth-basedReported 0.083 MG/L · MCL 0.08GA0110001ResolvedApr 1, 2022through Jun 30, 2022
Total Haloacetic Acids (HAA5)Health-basedReported 0.061 MG/L · MCL 0.06GA0110001ResolvedApr 1, 2022through Jun 30, 2022
Total Haloacetic Acids (HAA5)Health-basedReported 0.061 MG/L · MCL 0.06GA0110001ResolvedJan 1, 2022through Mar 31, 2022
TTHMGA0110001ResolvedOct 1, 2021through Dec 31, 2021

No reported violation does not prove that every contaminant was tested or absent; SDWIS measured values are incomplete and lag state records.

Solutions matcher

Your personalized water action plan

Matched to Maysville ZIP 30558 using 23.5 PPM nearby hardness and 3 reported measurement benchmarks.

1 match

Drinking water protection

Under-Sink Reverse Osmosis System

Total Haloacetic Acids (HAA5), TTHM have a measured benchmark flag or active health-based SDWIS record in this profile.

A certified multi-stage RO system targets a broader range of dissolved contaminants at the kitchen tap.

Explore under-sink filtration

Affiliate disclosure: we may earn a commission from qualifying purchases, at no added cost to you. Product matching is educational and does not replace certified water testing.

Frequently asked

Water questions for Maysville

Is tap water safe in Maysville?+

EPA ECHO shows no active health-based violation for the associated systems in this reporting snapshot. This does not prove every contaminant is absent; federal records can lag and household plumbing can change tap conditions.

How hard is the water?+

Nearby USGS observations produce an estimate of 23.5 PPM, or 1.4 grains per gallon, classified as soft. This is not a household tap measurement.

Do I need a water softener?+

There is no high-hardness trigger in this profile. Confirm with a tap test before buying equipment.