Skip to content

Local water dashboard

Official source aggregation

Water quality in Washington, IL 61571

A source-transparent look at local hardness, associated public water systems, EPA compliance history, and the measurements that are—and are not—available for Tazewell County.

1 active health-based violation
Primary matched system
Washington
Source water
Groundwater
County
Tazewell County
Profile updated

At a glance

What the current records say

Hardness

Very Hard

310 PPM · 18.1 GPG

Compliance screen

Review needed

1 active health-based record

Lead 90th percentile

0 mg/L

0% of action level

Utility match

3 systems

Serves 14,793 people system-wide

Hardness meter

How hard is the water?

Very Hard

Estimated local hardness

USGS hardness classification scale

310 PPM

Soft
0–59
Moderate
60–120
Hard
121–180
Very hard
181+

Parts per million

310

mg/L as CaCO₃ equivalent

Grains per gallon

18.1

1 GPG ≈ 17.1 PPM

What this means at home

At 310 PPM, mineral scale can build up on fixtures and heating elements, reduce soap lather, and leave visible spotting. Hardness is primarily an aesthetic and appliance concern—not itself a tap-water safety rating.

USGS sites used

40

Nearest site

23 mi

Observation range

May 22, 2017–Jul 30, 2025

Estimate confidence

Moderate

Median of the latest qualifying hardness observation at each nearby monitoring site. Nearest monitoring location: 11N 6E-24.1e1 (Well).USGS source documentation ↗

Regional context

Is 61571 typical?

These comparisons use other indexed ZIP estimates, not utility tap samples. They help show local context without replacing a household test.

Washington median

310 PPM

About the same

1 indexed ZIP readings · Range 310–310 PPM

Illinois median

285 PPM

25 PPM higher

1065 indexed ZIP readings · Range 115–408 PPM

EPA benchmark screen

Contaminant snapshot

Available numerical results from associated SDWIS community water systems, compared with the applicable action level or federal MCL. Federal measured-value coverage is incomplete.

1 pass1 fail

Lead (PB90)

0 mg/L

Reported Jun 30, 2026

Copper (CU90)

1.65 mg/L

Reported Jun 30, 2026

Numerical coverage

2 comparable results

Missing values remain blank; absence is not treated as a pass.

Lead (90th percentile)

Measured in mg/L

Pass

Local 0

EPA limit 0.015

Local level is 0% of the listed EPA limit.

Copper (90th percentile)

Measured in mg/L

Fail

Local 1.65

EPA limit 1.3

Local level is 127% of the listed EPA limit.

Share of EPA benchmark

100% line = listed limit

EPA SDWIS compliance

Reported violation history

Open EPA source documentation ↗
2026Q2
All records
11
Health-based
2
Active health-based
1
Contaminant or ruleSystemStatusPeriod
Public NoticeIL1795450ResolvedJul 12, 2025through Jan 2, 2026
Consumer Confidence RuleIL1790750ResolvedJul 1, 2025through Sep 5, 2025
Consumer Confidence RuleIL1795450UnaddressedJul 1, 2025
Consumer Confidence RuleIL1795450UnaddressedJul 1, 2024
Lead and Copper RuleIL1795450UnaddressedJul 1, 2024
Consumer Confidence RuleIL1795450ResolvedJul 1, 2024through Jul 15, 2024
Consumer Confidence RuleIL1795450ResolvedDec 4, 2023through Jul 15, 2024
Lead and Copper RuleHealth-basedIL1795450ResolvedApr 2, 2023through Jun 7, 2024
Lead and Copper RuleHealth-basedIL1795450UnaddressedMar 1, 2023
Lead and Copper RuleIL1795450ResolvedDec 30, 2022through Feb 7, 2023
Lead and Copper RuleIL1790750ResolvedDec 30, 2021through Jan 26, 2022

No reported violation does not prove that every contaminant was tested or absent; SDWIS measured values are incomplete and lag state records.

Solutions matcher

Your personalized water action plan

Matched to Washington ZIP 61571 using 310 PPM nearby hardness and 2 reported measurement benchmarks.

2 matches

Scale protection

High-Capacity Whole House Water Softener

310 PPM is 3× the high-hardness trigger used by this matcher.

Designed to reduce scale on fixtures, water heaters, glassware, and plumbing throughout the home.

Compare whole-house systems

Drinking water protection

Under-Sink Reverse Osmosis System

Copper (90th percentile), Lead and Copper Rule have a measured benchmark flag or active health-based SDWIS record in this profile.

A certified multi-stage RO system targets a broader range of dissolved contaminants at the kitchen tap.

Explore under-sink filtration

Affiliate disclosure: we may earn a commission from qualifying purchases, at no added cost to you. Product matching is educational and does not replace certified water testing.

Frequently asked

Water questions for Washington

Is tap water safe in Washington?+

EPA ECHO reports 1 active health-based violation among the associated community water systems. Review the affected utility's current notice and Consumer Confidence Report.

How hard is the water?+

Nearby USGS observations produce an estimate of 310 PPM, or 18.1 grains per gallon, classified as very hard. This is not a household tap measurement.

Do I need a water softener?+

At 310 PPM, a correctly sized whole-house softener can reduce scale and hard-water spotting. It does not replace contaminant filtration.