Skip to content

Berkshire County, Massachusetts

Great Barrington, MA water hardness: 212 PPM (12.4 GPG), very hard

Quick answer

Estimated hardness

212PPM

12.4 GPGVery Hard

Soft
0–60
Mod.
61–120
Hard
121–180
Very hard
181+

Nearby USGS regional estimate, not a tap test

  • 1 ZIP estimate
  • Low confidence
  • Typical nearest site 3.6 mi
  • Samples 2017–2018

Data updated

Nearby USGS samples put Great Barrington in the very hard range: the estimate is 212 PPM (12.4 GPG), 134 PPM above the Massachusetts median of 78 PPM and close to the U.S. median of 204 PPM.

Treat it as a rough guide: the estimate is rated low confidence, with the nearest qualifying site 3.6 miles away; the samples are groundwater, matching the main source EPA lists for Great Barrington Fire Dist.

Massachusetts median
78 PPM
Matched systems
3
ZIP estimate
212 PPM
How to test your tap →

At home

What very hard water means in Great Barrington

  • Heavy scale on fixtures, kettles and the dishwasher, often within days.
  • Scale shortens water-heater and appliance life; flush tanks and descale often.
  • Soap and detergent lather poorly; dry skin and stiff laundry are common complaints.

Test your own tap · Convert a test result

Do I need a water softener?

Usually worthwhile

Scale forms quickly and soap lathers poorly. Most households at this level benefit from softening.

Approximate softener load at the estimated 212 PPM (12.4 GPG), 60 gallons per person per day, no iron, regenerating about weekly.
HouseholdGrains per dayTypical size
2 people1,49024,000-grain
4 people2,98032,000-grain
6 people4,46048,000-grain

Based on a regional estimate, so re-run the calculator with your tap result before buying.

ZIP codes

Great Barrington water hardness by ZIP

Regional USGS estimate for each ZIP.

ZIPPPMGPG
01230Low confidence · 3.6 mi21212.4

Nearby cities

Water hardness near Great Barrington

Median of each city’s regional ZIP estimates, nearest first.

All 302 Massachusetts cities →
CityPPMGPG
MontereyBerkshire County · 6 mi19611.5
SheffieldBerkshire County · 6 mi20512.0
New MarlboroughBerkshire County · 7 mi18811.0
EgremontBerkshire County · 9 mi1549.0
StockbridgeBerkshire County · 9 mi1468.5
LeeBerkshire County · 10 mi804.7
West StockbridgeBerkshire County · 10 mi20912.2
OtisBerkshire County · 11 mi1227.1
SandisfieldBerkshire County · 11 mi1297.5
RichmondBerkshire County · 15 mi20912.2

Regional evidence

How reliable the Great Barrington estimate is

ZIPs with evidence
1 of 1
Median nearest site
3.6 mi
Observed
Jun 26, 2017 – Sep 25, 2018
Confidence
Low 1

1 distinct nearest monitoring site across the city's ZIPs. Main utility source: groundwater (Great Barrington Fire Dist). The city does not meet the stricter evidence rules used for state rankings.

Water systems and EPA records

3 matched water systems

EPA SDWIS snapshot 2026Q2, history from Jan 1, 2021. The largest system is shown first; records for one system do not apply to customers of another.

Great Barrington Fire Dist

Largest matched system · MA1113000 · Groundwater · 4,380 people served

No active health-based record

EPA SDWIS explicitly lists this ZIP in the system's served geography. Find this utility’s report →

Measurements (1)
  • Lead (90th percentile)

    EPA SDWIS Lead and Copper Rule samples · Jan 1, 2022 to Dec 31, 2024

    0.0029 mg/L vs 0.015 action level (19%)
    Below action level
Violation history (0)

No violation returned in this window.

2 smaller systems (1,891 people combined)
Housatonic Water WorksMA1113003 · Surface water · 1,391 people · 2 measurements · 10 violations

EPA SDWIS explicitly lists this ZIP in the system's served geography. Find this utility’s report →

  • Lead (90th percentile)

    EPA SDWIS Lead and Copper Rule samples · Jul 1, 2025 to Dec 31, 2025

    0.0026 mg/L vs 0.015 action level (17%)
    Below action level
  • Copper (90th percentile)

    EPA SDWIS Lead and Copper Rule samples · Jan 1, 2018 to Jun 30, 2018

    1.55 mg/L vs 1.3 action level (119%)
    Above action level
  • Public NoticeResolved · Oct 1, 2021 to Jan 21, 2022
  • Total Haloacetic Acids (HAA5) · Health-basedArchived · Oct 1, 2021 to Dec 31, 2021
  • Total Haloacetic Acids (HAA5) · Health-basedArchived · Jul 1, 2021 to Sep 30, 2021
  • Total Haloacetic Acids (HAA5)Resolved · Jul 1, 2021 to Sep 30, 2021
  • Lead and Copper RuleAddressed · Aug 7, 2017
  • Lead and Copper RuleAddressed · Jul 10, 2017
  • Long Term 2 Enhanced Surface Water Treatment RuleAddressed · Apr 1, 2015
  • Lead and Copper RuleAddressed · Jan 1, 2013
  • Lead and Copper RuleAddressed · Jan 1, 2013
  • Lead and Copper RuleAddressed · Jan 1, 2013
Bard College At Simons RockMA1113017 · Groundwater · 500 people · 1 measurement · 2 violations

EPA SDWIS explicitly lists this ZIP in the system's served geography. Find this utility’s report →

  • Lead (90th percentile)

    EPA SDWIS Lead and Copper Rule samples · Jan 1, 2022 to Dec 31, 2024

    0.0026 mg/L vs 0.015 action level (17%)
    Below action level
  • Groundwater RuleAddressed · Feb 1, 2015
  • Groundwater RuleAddressed · Sep 10, 2014

FAQ

Water questions for Great Barrington

How hard is the water in Great Barrington, MA?

Nearby USGS monitoring puts Great Barrington, MA at about 212 PPM (12.4 GPG), which is very hard. This is a regional estimate from environmental samples, not a tap test; your utility or a home test kit gives the delivered value.

Do I need a water softener in Great Barrington?

Usually worthwhile. At about 212 PPM (12.4 GPG) the water is very hard. Scale forms quickly and soap lathers poorly. Most households at this level benefit from softening. Confirm with a tap test before buying equipment.

Is Great Barrington water harder than the Massachusetts average?

Yes. At 212 PPM, Great Barrington is 134 PPM above the Massachusetts median of 78 PPM across indexed ZIP estimates, and close to the U.S. median of 204 PPM.

Is tap water in Great Barrington safe to drink?

EPA records show no active health-based violation for the 3 water systems matched to Great Barrington. Federal data can lag, so check your utility's latest Consumer Confidence Report. Hardness itself is not a health risk.