Skip to content

Camden County, Missouri

Camdenton, MO 65020 water hardness: 292 PPM (17.1 GPG), very hard

Quick answer

Estimated hardness

292PPM

17.1 GPGVery Hard

Soft
0–60
Mod.
61–120
Hard
121–180
Very hard
181+

Nearby USGS regional estimate, not a tap test

  • Low confidence
  • Nearest site 9.6 mi
  • 3 sites, 2016

Data updated

Nearby USGS samples put ZIP 65020 in the very hard range: the estimate is 292 PPM (17.1 GPG), 65 PPM above the Missouri median of 227 PPM.

Treat it as a rough guide: the estimate is rated low confidence, with the nearest qualifying site 9.6 miles away; the samples are groundwater, matching the main source EPA lists for Camdenton Pws.

Camdenton ZIPs
292 PPM
Missouri median
227 PPM
Largest utility
Camdenton Pws
Utility source
Groundwater
How to test your tap →

At home

What very hard water means in ZIP 65020

  • Heavy scale on fixtures, kettles and the dishwasher, often within days.
  • Scale shortens water-heater and appliance life; flush tanks and descale often.
  • Soap and detergent lather poorly; dry skin and stiff laundry are common complaints.

Test your own tap · Convert a test result

Do I need a water softener?

Usually worthwhile

Scale forms quickly and soap lathers poorly. Most households at this level benefit from softening.

Approximate softener load at the estimated 292 PPM (17.1 GPG), 60 gallons per person per day, no iron, regenerating about weekly.
HouseholdGrains per dayTypical size
2 people2,05024,000-grain
4 people4,10040,000-grain
6 people6,15064,000-grain

Based on a regional estimate, so re-run the calculator with your tap result before buying.

Nearby cities

Near Camdenton, MO

Median of each city’s regional ZIP estimates, nearest first.

All Missouri cities →
CityPPMGPG
Linn CreekCamden County · 6 mi29817.4
Macks CreekCamden County · 10 mi26415.4
Lake OzarkCamden County · 15 mi28216.5
StoutlandCamden County · 17 mi25114.7
Osage BeachMiller County · 13 mi30117.6
LaurieMorgan County · 17 mi28216.5

Regional evidence

Where the 292 PPM estimate comes from

USGS sites
3 (3 samples)
Nearest site
9.6 mi
Observed
Jun 9, 2016 – Aug 16, 2016
Confidence
Low

Median of the latest source-type-aligned hardness observation at each monitoring site within 25 miles (groundwater monitoring sites). Nearest: T37N R18W 07ABA1 (well). USGS data ↗

This estimate does not meet the stricter rules used for rankings.

Water systems and EPA records

6 matched water systems

EPA SDWIS snapshot 2026Q2, history from Jan 1, 2021. The largest system is shown first; records for one system do not apply to customers of another.

Camdenton Pws

Largest matched system · MO3010130 · Groundwater · 3,960 people served

No active health-based record

The system names this served city; Census place overlap links the city to this ZCTA. Find this utility’s report →

Measurements (1)
  • Lead (90th percentile)

    EPA SDWIS Lead and Copper Rule samples · Jan 1, 2023 to Dec 31, 2025

    0.0019 mg/L vs 0.015 action level (12%)
    Below action level
Violation history (1)
Violation history for Camdenton Pws
RuleStatusPeriod
LEAD AND COPPER RULE REVISIONSUnaddressedJul 2, 2025
5 smaller systems (1,957 people combined)
Camden County Pwsd 2MO3024091 · Groundwater · 1,600 people · 1 measurement · 3 violations

The system names this served city; Census place overlap links the city to this ZCTA. Find this utility’s report →

  • Lead (90th percentile)

    EPA SDWIS Lead and Copper Rule samples · Jan 1, 2022 to Dec 31, 2024

    0 mg/L vs 0.015 action level (0%)
    Below action level
  • LEAD AND COPPER RULE REVISIONSResolved · Oct 17, 2024 to Apr 16, 2025
  • Consumer Confidence RuleResolved · Jul 1, 2024 to Sep 5, 2024
  • Revised Total Coliform RuleResolved · Apr 1, 2023 to Apr 30, 2023
Brookview ApartmentsMO3079510 · Groundwater · 172 people · 1 measurement · 0 violations

The system names this served city; Census place overlap links the city to this ZCTA. Find this utility’s report →

  • Lead (90th percentile)

    EPA SDWIS Lead and Copper Rule samples · Jan 1, 2023 to Dec 31, 2025

    5.1e-4 mg/L vs 0.015 action level (3%)
    Below action level
Cedar GreenMO3190757 · Groundwater · 110 people · 1 measurement · 3 violations

The system names this served city; Census place overlap links the city to this ZCTA. Find this utility’s report →

  • Lead (90th percentile)

    EPA SDWIS Lead and Copper Rule samples · Jan 1, 2022 to Dec 31, 2024

    0.0015 mg/L vs 0.015 action level (10%)
    Below action level
  • Public NoticeResolved · Oct 10, 2024 to Oct 2, 2024
  • Revised Total Coliform Rule · Health-basedResolved · Aug 1, 2024 to Aug 31, 2024
  • Consumer Confidence RuleResolved · Jul 1, 2021 to Jul 7, 2022
J Bar H EstatesMO5031601 · Groundwater · 40 people · 2 measurements · 0 violations

The system names this served city; Census place overlap links the city to this ZCTA. Find this utility’s report →

  • Lead (90th percentile)

    EPA SDWIS Lead and Copper Rule samples · Jan 1, 2023 to Dec 31, 2025

    0 mg/L vs 0.015 action level (0%)
    Below action level
  • Copper (90th percentile)

    EPA SDWIS Lead and Copper Rule samples · Jan 1, 2011 to Dec 31, 2011

    1.523 mg/L vs 1.3 action level (117%)
    Above action level
Forest Ridge SubdivisionMO5031434 · Groundwater · 35 people · 1 measurement · 1 violation

The system names this served city; Census place overlap links the city to this ZCTA. Find this utility’s report →

  • Lead (90th percentile)

    EPA SDWIS Lead and Copper Rule samples · Jan 1, 2023 to Dec 31, 2025

    0 mg/L vs 0.015 action level (0%)
    Below action level
  • Consumer Confidence RuleResolved · Jul 1, 2023 to Nov 20, 2023

FAQ

Water questions for Camdenton 65020

How hard is the water in Camdenton, MO 65020?

Nearby USGS monitoring puts Camdenton, MO 65020 at about 292 PPM (17.1 GPG), which is very hard. This is a regional estimate from environmental samples, not a tap test; your utility or a home test kit gives the delivered value.

Do I need a water softener in ZIP 65020?

Usually worthwhile. At about 292 PPM (17.1 GPG) the water is very hard. Scale forms quickly and soap lathers poorly. Most households at this level benefit from softening. Confirm with a tap test before buying equipment.

Is ZIP 65020 water harder than the Missouri average?

Yes. At 292 PPM, ZIP 65020 is 65 PPM above the Missouri median of 227 PPM across indexed ZIP estimates, and above the U.S. median of 204 PPM.

Is tap water in ZIP 65020 safe to drink?

EPA records show no active health-based violation for the 6 water systems matched to ZIP 65020. Federal data can lag, so check your utility's latest Consumer Confidence Report. Hardness itself is not a health risk.