Skip to content

Local water dashboard

Official source aggregation

Water quality in Willacoochee, GA 31650

A source-transparent look at local hardness, associated public water systems, EPA compliance history, and the measurements that are—and are not—available for Atkinson County.

2 reported benchmark flags
Primary matched system
Willacoochee Water System
Source water
Groundwater
County
Atkinson County
Profile updated

At a glance

What the current records say

Hardness

Hard

134 PPM · 7.8 GPG

Compliance screen

No active flag

0 active health-based records

Lead 90th percentile

0.0034 mg/L

23% of action level

Utility match

1 system

Serves 1,723 people system-wide

Hardness meter

How hard is the water?

Hard

Estimated local hardness

USGS hardness classification scale

134 PPM

Soft
0–59
Moderate
60–120
Hard
121–180
Very hard
181+

Parts per million

134

mg/L as CaCO₃ equivalent

Grains per gallon

7.8

1 GPG ≈ 17.1 PPM

What this means at home

At 134 PPM, mineral scale can build up on fixtures and heating elements, reduce soap lather, and leave visible spotting. Hardness is primarily an aesthetic and appliance concern—not itself a tap-water safety rating.

USGS sites used

35

Nearest site

15.6 mi

Observation range

Jan 25, 2021–Mar 25, 2026

Estimate confidence

Moderate

Median of the latest qualifying hardness observation at each nearby monitoring site. Nearest monitoring location: 23J006 (Well).USGS source documentation ↗

Regional context

Is 31650 typical?

These comparisons use other indexed ZIP estimates, not utility tap samples. They help show local context without replacing a household test.

Willacoochee median

134 PPM

About the same

1 indexed ZIP readings · Range 134–134 PPM

Georgia median

40 PPM

94 PPM higher

469 indexed ZIP readings · Range 3–207 PPM

EPA benchmark screen

Contaminant snapshot

Available numerical results from associated SDWIS community water systems, compared with the applicable action level or federal MCL. Federal measured-value coverage is incomplete.

1 pass2 fail

Lead (PB90)

0.0034 mg/L

Reported Jun 30, 2026

Copper (CU90)

Not available

No numerical 90th-percentile result

Numerical coverage

3 comparable results

Missing values remain blank; absence is not treated as a pass.

Lead (90th percentile)

Measured in mg/L

Pass

Local 0.0034

EPA limit 0.015

Local level is 23% of the listed EPA limit.

Gross Alpha, Excl. Radon and U

Measured in PCI/L

Fail

Local 24

EPA limit 15

Local level is 160% of the listed EPA limit.

Combined Radium (-226 and -228)

Measured in PCI/L

Fail

Local 6

EPA limit 5

Local level is 120% of the listed EPA limit.

Share of EPA benchmark

100% line = listed limit

EPA SDWIS compliance

Reported violation history

Open EPA source documentation ↗
2026Q2
All records
14
Health-based
9
Active health-based
0
Contaminant or ruleSystemStatusPeriod
Gross Alpha, Excl. Radon and UHealth-basedReported 24 PCI/L · MCL 15GA0030001ArchivedOct 1, 2025through Dec 31, 2025
Gross Alpha, Excl. Radon and UHealth-basedReported 24 PCI/L · MCL 15GA0030001ArchivedJul 1, 2025through Sep 30, 2025
Combined Radium (-226 and -228)Health-basedReported 6 PCI/L · MCL 5GA0030001ResolvedJul 1, 2025through Sep 30, 2025
Combined Radium (-226 and -228)Health-basedReported 6 PCI/L · MCL 5GA0030001ResolvedApr 1, 2025through Jun 30, 2025
Gross Alpha, Excl. Radon and UHealth-basedReported 25 PCI/L · MCL 15GA0030001ArchivedApr 1, 2025through Jun 30, 2025
Gross Alpha, Excl. Radon and UGA0030001ResolvedJan 1, 2025through Mar 31, 2025
Combined UraniumGA0030001ResolvedJan 1, 2025through Mar 31, 2025
Gross Alpha, Excl. Radon and UHealth-basedReported 19 PCI/L · MCL 15GA0030001ArchivedJan 1, 2025through Mar 31, 2025
Combined Radium (-226 and -228)GA0030001ResolvedJan 1, 2025through Mar 31, 2025
Gross Alpha, Excl. Radon and UHealth-basedReported 20 PCI/L · MCL 15GA0030001ArchivedOct 1, 2024through Dec 31, 2024
Gross Alpha, Excl. Radon and UHealth-basedReported 18 PCI/L · MCL 15GA0030001ArchivedJul 1, 2024through Sep 30, 2024
Gross Alpha, Excl. Radon and UHealth-basedReported 16 PCI/L · MCL 15GA0030001ArchivedApr 1, 2024through Jun 30, 2024
E. COLIGA0030001ResolvedNov 5, 2022through Nov 8, 2022
Public NoticeGA0030001ResolvedNov 3, 2022through Nov 8, 2022

No reported violation does not prove that every contaminant was tested or absent; SDWIS measured values are incomplete and lag state records.

Solutions matcher

Your personalized water action plan

Matched to Willacoochee ZIP 31650 using 134 PPM nearby hardness and 3 reported measurement benchmarks.

2 matches

Scale protection

High-Capacity Whole House Water Softener

134 PPM is 1× the high-hardness trigger used by this matcher.

Designed to reduce scale on fixtures, water heaters, glassware, and plumbing throughout the home.

Compare whole-house systems

Drinking water protection

Under-Sink Reverse Osmosis System

Gross Alpha, Excl. Radon and U, Combined Radium (-226 and -228) have a measured benchmark flag or active health-based SDWIS record in this profile.

A certified multi-stage RO system targets a broader range of dissolved contaminants at the kitchen tap.

Explore under-sink filtration

Affiliate disclosure: we may earn a commission from qualifying purchases, at no added cost to you. Product matching is educational and does not replace certified water testing.

Frequently asked

Water questions for Willacoochee

Is tap water safe in Willacoochee?+

EPA ECHO shows no active health-based violation for the associated systems in this reporting snapshot. This does not prove every contaminant is absent; federal records can lag and household plumbing can change tap conditions.

How hard is the water?+

Nearby USGS observations produce an estimate of 134 PPM, or 7.8 grains per gallon, classified as hard. This is not a household tap measurement.

Do I need a water softener?+

At 134 PPM, a correctly sized whole-house softener can reduce scale and hard-water spotting. It does not replace contaminant filtration.