Skip to content

Local water dashboard

Official source aggregation

Water quality in Orlando, FL 32827

A source-transparent look at local hardness, associated public water systems, EPA compliance history, and the measurements that are—and are not—available for Orange County.

4 active health-based violations
Primary matched system
Orlando Utilities Commission
Source water
Groundwater
County
Orange County
Profile updated

At a glance

What the current records say

Hardness

Very Hard

360 PPM · 21.1 GPG

Compliance screen

Review needed

4 active health-based records

Lead 90th percentile

0.0016 mg/L

11% of action level

Utility match

10 systems

Serves 536,466 people system-wide

Hardness meter

How hard is the water?

Very Hard

Estimated local hardness

USGS hardness classification scale

360 PPM

Soft
0–59
Moderate
60–120
Hard
121–180
Very hard
181+

Parts per million

360

mg/L as CaCO₃ equivalent

Grains per gallon

21.1

1 GPG ≈ 17.1 PPM

What this means at home

At 360 PPM, mineral scale can build up on fixtures and heating elements, reduce soap lather, and leave visible spotting. Hardness is primarily an aesthetic and appliance concern—not itself a tap-water safety rating.

USGS sites used

73

Nearest site

6.9 mi

Observation range

Jan 13, 2016–May 27, 2026

Estimate confidence

Moderate

Median of the latest qualifying hardness observation at each nearby monitoring site. Nearest monitoring location: ORANGE WELL NO. 7 AAK1369 (Well).USGS source documentation ↗

Regional context

Is 32827 typical?

These comparisons use other indexed ZIP estimates, not utility tap samples. They help show local context without replacing a household test.

Orlando median

357 PPM

About the same

16 indexed ZIP readings · Range 353–360 PPM

Florida median

280 PPM

80 PPM higher

602 indexed ZIP readings · Range 20–374.5 PPM

EPA benchmark screen

Contaminant snapshot

Available numerical results from associated SDWIS community water systems, compared with the applicable action level or federal MCL. Federal measured-value coverage is incomplete.

1 pass1 fail

Lead (PB90)

0.0016 mg/L

Reported Dec 1, 2025

Copper (CU90)

2.4 mg/L

Reported Jun 30, 2000

Numerical coverage

2 comparable results

Missing values remain blank; absence is not treated as a pass.

Lead (90th percentile)

Measured in mg/L

Pass

Local 0.0016

EPA limit 0.015

Local level is 11% of the listed EPA limit.

Copper (90th percentile)

Measured in mg/L

Fail

Local 2.4

EPA limit 1.3

Local level is 185% of the listed EPA limit.

Share of EPA benchmark

100% line = listed limit

EPA SDWIS compliance

Reported violation history

Open EPA source documentation ↗
2026Q2
All records
109
Health-based
4
Active health-based
4
Contaminant or ruleSystemStatusPeriod
Revised Total Coliform RuleFL3480226ArchivedMar 1, 2026through Mar 31, 2026
E. COLIFL3480226ArchivedMar 1, 2026through Mar 31, 2026
Revised Total Coliform RuleFL3480555ArchivedMar 1, 2026through Mar 31, 2026
E. COLIFL3480555ArchivedMar 1, 2026through Mar 31, 2026
Revised Total Coliform RuleFL3484119ArchivedAug 1, 2025through Aug 31, 2025
Revised Total Coliform RuleFL3481155ArchivedAug 1, 2025through Aug 31, 2025
E. COLIFL3481155ArchivedAug 1, 2025through Aug 31, 2025
Revised Total Coliform RuleFL3480149ArchivedJul 1, 2025through Jul 31, 2025
Consumer Confidence RuleFL3481270UnaddressedJul 1, 2025
Consumer Confidence RuleFL3480255UnaddressedJul 1, 2025
Consumer Confidence RuleFL3481518UnaddressedJul 1, 2025
Consumer Confidence RuleFL3481199UnaddressedJul 1, 2025
Consumer Confidence RuleFL3480265UnaddressedJul 1, 2025
Consumer Confidence RuleFL3481016UnaddressedJul 1, 2025
Consumer Confidence RuleFL3481571UnaddressedJul 1, 2025
Consumer Confidence RuleFL3480226UnaddressedJul 1, 2025
Consumer Confidence RuleFL3480555UnaddressedJul 1, 2025
Consumer Confidence RuleFL3484175UnaddressedJul 1, 2025
Consumer Confidence RuleFL3481155UnaddressedJul 1, 2025
Lead and Copper RuleFL3481155UnaddressedJul 1, 2025

No reported violation does not prove that every contaminant was tested or absent; SDWIS measured values are incomplete and lag state records.

Solutions matcher

Your personalized water action plan

Matched to Orlando ZIP 32827 using 360 PPM nearby hardness and 2 reported measurement benchmarks.

2 matches

Scale protection

High-Capacity Whole House Water Softener

360 PPM is 3× the high-hardness trigger used by this matcher.

Designed to reduce scale on fixtures, water heaters, glassware, and plumbing throughout the home.

Compare whole-house systems

Drinking water protection

Under-Sink Reverse Osmosis System

Copper (90th percentile) has a measured benchmark flag or active health-based SDWIS record in this profile.

A certified multi-stage RO system targets a broader range of dissolved contaminants at the kitchen tap.

Explore under-sink filtration

Affiliate disclosure: we may earn a commission from qualifying purchases, at no added cost to you. Product matching is educational and does not replace certified water testing.

Nearby indexed reports

Compare ZIPs in Orlando

Estimates can differ across a city because monitoring locations and associated systems differ.

View all Orlando reports →

Frequently asked

Water questions for Orlando

Is tap water safe in Orlando?+

EPA ECHO reports 4 active health-based violations among the associated community water systems. Review the affected utility's current notice and Consumer Confidence Report.

How hard is the water?+

Nearby USGS observations produce an estimate of 360 PPM, or 21.1 grains per gallon, classified as very hard. This is not a household tap measurement.

Do I need a water softener?+

At 360 PPM, a correctly sized whole-house softener can reduce scale and hard-water spotting. It does not replace contaminant filtration.